ZKTeco NVR Kit Setup Guide, Firstly, thank you for purchasing this terminal, before use, please read this manual carefully to avoid the
unnecessary damage! The company reminds you that the proper user will improve the use affect and
authentication speed.

No written consent by our company, any unit or individual isn’t allowed to excerpt, copy the content of
this manual in part or in full, also spread in any form.


The product described in the manual maybe includes the software which copyrights are shared by the
licensors including our company, Except for the permission of the relevant holder, any person can’t copy,
distribute, revise, modify, extract, decompile, disassemble, decrypt, reverse engineering, leasing,
transfer, sub-license the software, other acts of copyright infringement, but the limitations applied to the
law is excluded

1. Device Installation and Cable Connection for Internet Access

Device Installation and Cable Connection for Internet Access

Networking of IPC Suite

2Q==

Device Installation

©Notes:

For the installation method of MD532, see the

IR5+MD5+IP5-IP Camera User Manual

.

For the installation method of F7, see the

F7 Installation Guide and User Manual

.

For the installation method of NVR, see the

NVR User Manual

.

Cable Connection for Internet Access

Install the devices, power them on, and then connect the NVR device, four MD532 devices, and the F7 device to the Internet by using network cables.

O Note: For detailed description of cable connection, see the corresponding user manuals of the devices.

1

 

Megapixel IP Camera with 4CH NVR Kit

1.3.1 Connecting the MD532 to the Internet

2Q==

I . Connect the power cables and power on the MD532.

Connect the MD532 to the switch by using network

 

cables for Internet access.

 

ZKTeco NVR Kit Setup Guide

Read More : Xmeye NVR Installation and User Guide

1. Reset Key

2. Network Interface

3. Power Interface

4. DV 12V

5. Network Cable

6. Switch

Connecting the Access Device to the Internet

(The following takes F7 as an example.)

2Q==

Z

I. Install the access control device (F7) and power on it.

Notes:

Installation of access control device is required only if

 

the suite contains an access control device.

For the suite of standard configuration, the F7 access

 

control all-in-one device is used. However, the following

 

access control products are also supported: F8, F18,

 

MA300, TF1700 and F9.

n. Connect the F7 to the switch by using network cables
for Internet access.

 

1. Device Installation and Cable Connection for Internet Access

Connecting the NVR to the Internet

NVR cable connection ports

9k=

1. 485 Interface

4. VGA Video Output Interface

6. Power Button

9. Network Interface

2. Alarm Interface

5. USB Interface

7. Audio Output

10. Power Interface

3. CBVS Video Output Interface

8. Audio Input

I . Use the CBVS or VGA video output mode, and connect the display device by using corresponding

connection cables.

Connect the power cables and power on the NVR

n. Connect the NVR to the switch by using network cables for Internet access.

NVR networking

9k=

1. NVR

2. Network Cable

3. VGA Cable

4. Switch

5. LCD

3

 

Megapixel IP Camera with 4CH NVR Kit

Device Access

Using the Software of the NVR

Startup

Connect the power cables and press the power button (in the ON state). The power indicator is lit, and the NVR starts. The multi-screen video output mode is enabled by default. If the startup time is within the scheduled record time, the system automatically enables the scheduled recording function and operates properly.

Login to the system

After successful startup, right-click the mouse and choose and click Main Menu in the shortcut menu. The SYSTEM LOGIN dialog box will display. Enter the user name and password in the corresponding input boxes.

^ Notes:

Two default users are available in the system: user

admin

and user

guest

. The default password of the two users is

123456

.

A password security policy is executed. You can try a password only five times within 30 minutes. After that, the account is locked.

Device configuration

Choose

Main menu

>

Advanced

>

Digital Channel

to access the

Digital Channel

window.

Choose a channel No. besides

Channel

, and double-click the default configuration in

Config List

to access the

Remote Channel Config window.

Click

Device search

. The system automatically searches the devices in the same network segment as the NVR had already connected to the Internet.

Click to select a device in the Device List area, and then click the

Save

button to return to the

Remote Channel Config

window in which relevant information about this device will display.

Click the

Save

button to return to the

Digital Channel

window, enable the

Enable

( indicates that this function is enabled), and then click the

Save

button in the

Digital Channel

window.

Right-click the mouse to return to the monitoring window in which monitoring pictures of the devices configured are displayed in real time.

2.2 Using the Network Video Surveillance Software

The bundled optical disk contains the Surveillance Client Software provided by the company for free, implementing simultaneous management and real-time monitoring over multiple IP cameras. Please install the software in the bundled optical disk, start the software, and add devices to the system for real-time monitoring. For details about how to use the network video surveillance software, see the ZKiVision Client Software User Manual in the bundled optical disk.

4

 

2 Device Access

Adding a Device to the ZKiVision Client Software

Start and log in to the Surveillance Client Software (the default login account and password are respectively admin and 123456).

Login

User name:

User password:

Z

a Remember

Login Exit Change PW

After adding the NVR, MD532, and F7 devices to the Surveillance Client Software and setting the access control function, users can use the Surveillance Client Software to implement linkage between video and access control.

Adding NVR and MD532

(This document takes the method of adding the NVR as an example. The method of adding the MD532 is the same as

that of adding the NVR.)

2.

Click

1. Click the Settings icon

Z

to access the device Search window.

9k=

Z

and then ’■

Search new devices

to search all NVR and MD532 devices that are connected

to the Internet but not added to this software, as shown in the following figure.

5

 

Megapixel IP Camera with 4CH NVR Kit

Z

3. In the Device List area, select the device to be added to this software. The following figure provides an example of

adding the NVR device to the software.

9k=

4. Click OK to access the Device Information Setting window.

6

 

2 Device Access

2Q==

The

Unpartitioned cameras

area displays the device selected in

Step 3

.

No area is added to the software if the software is used for the first time. You can enter an area name besides

Area name

and click

Add

to add an area for the software. (For example, enter

Local

besides

Area name

and click

Add

to add an area, as shown in the preceding figure.)

Click to select the device in the

Unpartitioned cameras

area, and modify device information as required. Click the button besides

Select areas

, and select an area in the drop-down list. After that, click the

Test

button. If the device

connection is successful, the Connection succeeded prompt will display, as shown in the following figure.

9k=

©Note: Password in the Device Info. area indicates the device connection password. If this password is incorrect, the device cannot be successfully connected.

Click

OK

to close the prompt. Click

Add

to add the NVR device. After the NVR device is successfully added, it wills

display in the Video Device List, as shown in the following figure.

7

 

Megapixel IP Camera with 4CH NVR Kit

Z

©Note: Keep on adding MD532 devices to this system according to Steps 1-8. After adding all devices to be added,

click the Preview icon

, the list of devices already added to the software will display on the left of the window, and

the real-time monitoring pictures of the IP cameras (MD532) already added to the software are displayed in the preview

window, as shown in the following figure.

9k=

2.2.1.2 Adding Access Control Device

(Note: That this operation is required only when the suite contains an access control device.)

1.

Click the Access Control Function icon

9k=

to access the Access Management window (The following

takes F7 as an example.).

 

2 Device Access

Z

Input the Access Name, IP address, and Port No. in the

Access Name

,

IP address

, and

Port

text boxes respectively.

After that, click the Test button. If the device connection is successful, the Connection succeeded prompt will

display, as shown in the following figure.

9k=

Click

OK

to close the prompt and then click

Add

. A prompt as shown in the following figure will display.

2Q==

Click

OK

to confirm and add the access device. After the device is successfully added, relevant information about it

will display in the Access List area, as shown in the following figure.

9

 

Megapixel IP Camera with 4CH NVR Kit

9k=

2.2.2 Setting for Linkage between Access Control and Video

(Note: That this operation is required only when the suite contains an access control device.)

You can set alarm linkage for the video device and access device to implement linkage between access control and video. The detailed operation procedure is as follows:

Alarm Linkage Setting

In the

Access Management

window, double-click the camera in the

Video Device List

.

In the

Access List

, select the access device requiring alarm linkage, as shown in the following figure.

2Q==

Click

Save

. A prompt as shown in the following figure will display.

10

 

2 Device Access

9k=

Click

OK

to confirm and save the current data. A prompt as shown in the following figure will display after the data is

successfully saved. (You can click OK to close the prompt.)

5.

Click

Alarm setting

2Q==

to access the Alarm Setting window.

Double-click the camera in the

Video Device List

, click to select an alarm input signal in the

Input Signal List

area (take

Open door normally

as an example), and click to select linkage actions in the

Linkage Action List

area, as shown in the following figure.

9k=

Click

Save

. A prompt as shown in the following figure will display.

Z

11

 

Megapixel IP Camera with 4CH NVR Kit

Click

OK

to confirm and save the current data. A prompt as shown in the following figure will display after the data is successfully saved.

2Q==

Click

OK

to close the prompt.

Camera Arming Setting

2.

1. Click the Preview icon

2Q==

to access the Preview window.

Right-click the camera, and choose All arming in the shortcut menu, as shown in the following figure.

2Q==

Viewing the Effects of the Linkage between Access Control and Video

When a user opens door normally by using fingerprint on the access device (F7), a linkage alarm popup window will show and it will start video recording accordingly:

12

 

2 Device Access

9k=

Access Event

©Note: Users can click the Events Search icon

9k=

and then the

button to view the

video recording. For detailed operations, refer to the bundled optical disk ZKiVision Client Software User Manual.

 